-
Electro Surgical Generator : SSE-300
$670Original price was: $670.$600Current price is: $600.Technical Specification
300 Watt analog model with basic cut, coagulation and bipolar modes with capability of doing most of the surgeries with lowest price
Max Power: 300 Watt
Programs: NA
Monopolar Modes: Cut and Coagulation
Bipolar Mode: Cut and Coagulation
Tissue Response Circuit: NA
Patient Plate Monitoring System: NA
APPLICATION/RELEVANCE
Microsurgery
Neurosurgery
Plastic surgery
Standard Accessories
Surgical Monopolar Active handle Valley Type
Patient Plate & Cord
Disposable Hand Switch Pencil
Double Paddle Foot Switch
Bipolar Forceps Bayonet & Cable
-
Electro Surgical Generator : Victor XL
$1,450Original price was: $1,450.$1,350Current price is: $1,350.Victor XL is a high performance micro controller based model With 20 programs with host of features and modes for all around superior capabilities. This is the right model for the customers who require all the features and controls at a reasonable price.
Quick Reference Power Digital : 400 W Programs : 20 Capability : All surgeries Higher end for collective use
Technical Specification Max Power : 400W Display: Graphical LCD Display Programs: 20 Monopolar Cut Modes : Pure Cut, Blend1, Blend2, Endo Cut Monopolar Coagulation Modes: Spray, Dessicate, Fulgurate. Bipolar Modes: Micro, Macro, Cut. Tissue Response Circuit: Present Patient Plate Monitoring System: Present Dimension (WxHxD) : 300 mm x 150 mm x 340 mm Supplied with all standard accessories
Power socket will be be provided free of cost as per country requirement.
-
Electro Surgical Generator : Victor XL Plus
$1,600Original price was: $1,600.$1,500Current price is: $1,500.Victor XL Plus is a top of the line micro controller based model with 99 programs, high speed tissue response circuit and host of modes and superior bipolar performance for the customers who demand the best. Quick Reference Power Digital : 400 W Programs : 99 Capability : All surgeries Top of the line model.
Technical Specification Max Power : 400W Display: Graphical LCD Display Programs: 99 Monopolar Cut Modes : Pure Cut, Blend1, Blend2, Endo Cut Monopolar Coagulation Modes: Spray, Dessicate, Fulgurate. Bipolar Modes: Micro, Macro, Cut. Tissue Response Circuit: Present Patient Plate Monitoring System: Present Dimension (WxHxD) : 300 mm x 150 mm x 340 mm Supplied Accessories For accessories detail please check the photograph Power socket will be be provided free of cost as per country requirement.
Dimension (WxHxD): 300 mm x 150 mm x 340 mm
-
Electro Surgical Generator 400W : OEM
$1,500Original price was: $1,500.$1,000Current price is: $1,000.SPECIFICATION
Automatically stops energy delivery as soon as the seal the cycle is complete
Minimum cutting effect
Feedback-controlled response system
Bipolar output with a nonsparking characteristic
Prompt start even in irrigated procedures
Spray coagulation
Pure and smooth cut
Provides good hemostasis effect
Available voltage: 110V/220V, 50hz AC
Technical Specification
Max Power : 400W Display : 7 Segment Digital Programs : 99 Monopolar Cut Modes : Pure Cut, Blend, Blend2, Endo Cut Monopolar Coagulation Modes : Spray, Dessicate, Fulgurate Bipolar Modes : Micro, Macro, Cut Tissue Response Circuit : Present Patient Plate Monitoring System : Present Dimension (WxHxD) & Weight : 4.5" x 10" x 11" & 3.8Kg. APPLICATION/RELEVANCE
Microsurgery
Laparoscopy
Neurosurgery
Reconstructive surgery
Plastic surgery
Standard Accessories
Sr no Particular No’s of pcs. 1 Surgical Monopolar active handle valley lab type. 1nos 2 Needle set (electrodes set for above probe) 1nos 3 S.S. patient plate (adult) 1nos 4 Patient plate cable cord. 1nos 5 Hand switch pencil DISPOSABLE.(1time use) 1nos 6 Double paddle footswitch. 1nos 7 Bipolar forceps REGULAR bayonet. 1nos 8 Bipolar forceps cable cord. 1nos 9 Single paddle foot switch 1nos -
Electro Surgical Generator 400W : Excel Sealer
$3,000Original price was: $3,000.$2,800Current price is: $2,800.Vessel Sealing System
(CE Certified)
(Model: Excel Sealer)
SPECIFICATION
99 Programs Mode: User Settable Program Mode
Frequency: 480KHz (Monopolar)
Frequency: 1MHz (Seal Mode)
Display: Touch Screen
Weight: 7.5Kg (Approx.)
Dimension: L440 x W355 x H155 mm Available voltage: 110V/220V, 60Hz/50Hz AC
Technical Specifications
Cut MODE MAX POWER LOAD CREAST FACTOR PURE CUT 400W 300Ω 1.5 BLEND 1 250W 300Ω 1.5 BLEND 2 200W 300Ω 1.5 ENDOCUT 99% 300Ω 1.5 COAG MODE MAX POWER LOAD CREAST FACTOR SPRAY 120W 300Ω 7 FORCE 120W 300Ω 6.5 FULGURATE 150W 300Ω 6 DESICCATE 150W 300Ω 6 BIPOLAR/SEAL MODE MAX POWER LOAD CREAST FACTOR BI-COAG 80W 100Ω 1.5 BI-CUT 80W 100Ω 1.5 AUTO 100W 100Ω 1.5 SEAL 150W 100Ω 1.5 Standard Accessories
- Chuck Handle with Electrode
- Bipolar Forcep with Cable
- Monopolar / Bipolar & Seal Double Paddle Foot Switch
- Disposable Hand Switch Pencil
- Patient Plate with Cord
- Power Socket/Cable as per country requirement
Sealer Accessories are optional
(You have to pay extra for it)
-
Electro Surgical Generator 400W : Max Seal
$3,600Original price was: $3,600.$3,300Current price is: $3,300.Vessel Sealing Systems
Model: MaxSeal
Multiple modes for superior functionality
Multiple Modes - 2 Cut modes,
5 Blend modes
3 EndoCut modes
2 Spray modes
2 Fulgurate modes
1 Dessicate mode
1 Bi-Cut mode
2 Bi-coag mode and 1 Seal mode for all types of procedures and all types of desired settings for superior performance.
100 Programs memory
100 programs memory to save all desired settings for all different cases. Recall on program selection.
Enertech's vessel sealing systems give you something no other electro surgical tool can – permanent vessels occlusion. This revolutionary technology replaces almost all other hemostatic tools because it doesn't just ligate vessels, it actually fuses vessel walls to create a permanent seal.
Across the range, Enertech Vessel Sealing technology delivers a unique combination of pressure and energy to create a consistent seal with each application :-
Shorter operating time - save almost upto 75% operating time.
Permanently fuses vessels upto and including 7 mm diameter and tissue bundles without dessication or isolation.
Faster and safer patient recovery.
Seals withstand 3 times normal systolic blood pressure.
Uses bodies own collagen, no requirement to insert foreign material into patient body which can cause complications.
Feedback controlled response system automatically discontinues energy delivery when the seal is complete, eliminating the guess work.
Each of the devices comprises with high power and low voltage bipolar mode and specialist
instruments that combine tissue compression with tissue heating to produce hemostasis in veins or a bundle of tissue.
The Product is delivered through a variety of Instruments for use in both Laparoscopic and open procedures in a range of surgical specialties, including gynecological, colorectal, urology and general surgery.
Performance Features
Patient plate conductivity monitoring system ( PP - CMS ) :
The advanced monitoring system gives a Real Time indication of the quality of the conductivity via the patient plate. There are 3 indicators. H = High contact and good conductivity. M = Medium Contact and medium conductivity. L = Low contact and poor conductivity. This Feature enables the monitoring of contact quality and hence significantly reduces the chances of plate failure resulting in burns
Accessories contact detection during plug in and operation :
Accessories are detected during plug in and indicator for the footswitch turns red with words “FS” indicating that the same are ready for operation. During Press mode the indicator turns green showing which mode has been activated, reducing chances of wrong mode operation.
For Technical Detail please see the listed photograph
The unit will be supplied with Electrosurgical Generator standard accessories.
Vessel Sealer accessories are optional.
Dimension ( W x H x D ) : 300 mm x 150 mm x 340 mm
Input Supply Voltage : 110V/ 230 VAC 50/60Hz
Weight : 5.5 kg
Power socket will be be provided free of cost as per country requirement.
-
Electro Surgical Generator Diathermy Mono polar +Bio Polar : Ensurg- 300
$980Original price was: $980.$960Current price is: $960.Ensurg 300 is micro controller based model with 6 programs, best price performance ratio in similar class of generators offered by other manufactures and can be widely used in procedures including urology, GI, Gynecologic, Orthropedic, Thoracic and Plastic Surgery. Power Digital : 300W Programs: 06 Capability: All surgeries but till 300 W powerIdeal where 400 W not required. Performance Features: Real Time Tissue Response Technology: Real Time Tissue Response Technologies provides surgeons with superior performance at lower power setting, minimizing the risk of tissue damage and neuromuscular stimulation. Patient Plat Return Electrode Monitoring System: Patient Plate Return Electrode Monitoring System provide instant indication of the quality of contact of the patient plate return electrodes, Failure of poor contact result in fault indication with sound alarm which substantially reduces the risk of burn under the patient return electrode. High Power Efficiency of 97%: The power efficiency of Enertech generators are the highest in it’s class 97%. This leads to multiple benefits like increased reliability, most compact size, high portability, economy and reduced power consumption. Technical Specification: Max Power: 300w Display: 7 Segment LED Digital. Programs: 6 Monopolar Cut Modes: Pure Cut, Blend1, Blend2, Endo Cut. Monopolar Coagulation Modes: Spray, Dessicate, Fulgurate. Bipolar Modes: Micro, Macro. Tissue Response Circuit: Present Patient Plate Monitoring System : Present Dimension (WxHxD) & Weight: 300 mm x 150 mm x 340 mm & 5.5 kg. Supplied with all standard accessories For accessories detail please see photograph Power socket will be be provided free of cost as per country requirement. -
ELECTROSURGICAL SKIN CAUTERY Machine : Byfrecator
$370Original price was: $370.$300Current price is: $300.SPECIAL FEATURES
Offers good choice of monopolar and Bipolar current.
Portable model attached with briefcase for safe handling.
Intensity variable accurately ( 50 to 100 watts output).
Ideal for minor and instant coagulation, dessiction and fulgeration.
Useful for E.N.T Surgeons, Dermatologists, General Surgeons and Cosmetologists.
APPLICATION
To Remove skin tags, warts, corns, Hair Restoring surgery, Forehead lift, Ablation of keloides, Palatoplasty, Kerotosis, Blephare plasty, Ritodoplasty, Leason removal, Tumottrs, Rehinepliyma, Epilation, Nipple reduction, Face lifts, Mamoplasty, Epistaxis, Augmentation, Development of skin flaps, To,gue Lession Removal, Abdominoplasty, Biopsies
Dermatology treatments
Cosmology Treatments
Collagen Remodeling
Skin Treatments
Ablation & Non ablation
Beauty Treatment
Plastic Surgery
Supplied Accessories
Surgical handle : 01 No. 5 Electrodes, : 05 Nos. Foot Switch : 01 No. Inactive Plate : 01 No. Tweezers with cable : 01 No. Main Cable : 01 No. Operating Manual : 01 No.
Power socket will be provided free of cost as per country requirement.
Technical Data
Intensity variable accurately (50 to 100 watts output).
Power supply: 110/220 V
-
RF CAUTERY 2Mhz – Radio Surgery with High Frequency
$585Original price was: $585.$570Current price is: $570.The Technique of Radio Surgery involves the passage of high frequency radio waves ( 2 Mhz – megahertz) through soft tissue to cut, coagulate, or remove the tissue. Soft tissue resistance to there radio waves caused the cellular water in the soft tissue to heat, which produces steam, an results in cellular molecular dissolution of individual tissue cells.
The surgeon uses a hand piece with an active electrodes (different type of electrodes for different applications) to transmit the radio waves. The radio waves are focused on the tissue by an antenna plat ) Patient plate) that is positioned behind the tissue in contact with patient’s skin. Radio surgery in general practice has many advantages over conventional surgical techniques particularly dermatological, plastic and eye lid surgery, ENT Dental, quicker operating time; rapid healing, less tissue damage and less post operative discomfort have been observed and its wider use in hospital practice is recommended. Radio frequency is not to be confused with electro-surgery machine ( surgical diathermy) spark gap circuitry unit ( electro cautery) and uses completely new technique compared with scalpel surgery and other techniques and Radio energy does the cutting very light. A very high frequency radio wave 0-3-2 MHz and a fine needle or wire loop electrode which is held by the surgeon, radio energy passes between the cautery electrode and patient plate. It is concentrated at the needle end or wire loop electrode, resulting in the release of energy, which produces steam within the cells, thus vaporizing them and dividing the tissues. Standard Accessories: Monopolar Handle – 01 No. Patient Plate – 01 No. Electrodes - 01 Set Foot Switch – 01 No. Hand Switch – 01 No. Bipolar / forceps – 01 No. Cleaning Knife – 01 No. Power cable: 01 No. Operating manual: 01 No. Specification: Power Input 110 volts/220 volts Power consumption 150 Watts. Frequency 2 MHz Maximum Output: HF Monopolar 150 Watts on 400 ohm load HF Bipolar 100 Watts on 100 ohm load Coagulation 100 Watts on 1000 ohm Size: 8½ " x 7½ " x 4" Weight: 3.5 Kgs